User manual FRIGIDAIRE CPEH3077RF

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual FRIGIDAIRE CPEH3077RF. We hope that this FRIGIDAIRE CPEH3077RF user guide will be useful to you.


FRIGIDAIRE CPEH3077RF : Download the complete user guide (1782 Ko)

Manual abstract: user guide FRIGIDAIRE CPEH3077RF

Detailed instructions for use are in the User's Guide.

[. . . ] Front view Typical cabinet installation Side view 29 7/8" 30” Minimum Minimum to wall on either side of range above 36” height. 1” 30” Minimum* 18” Minimum to cabinets on either side of range 13” Maximum depth for cabinets above range top. 36” 36 3/8" ± 1/4" Maximum 30” Minimum 26" 0” clearance below cooking top and at rear of range Do or 46" op en * 30" minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet; or 24 " minimum when bottom of wood or metal cabinet is protected by not less than ¼" flame retardant millboard covered with not less than no. Follow all dimension requirements provided above to prevent property damage, potential fire hazard, and incorrect countertop and cabinet cuts. [. . . ] Drill Pilot Holes and Fasten Bracket - Drill a 1/8" pilot hole where screws are to be located. Use a 5/16" nut-driver or flat head screwdriver to secure the bracket in place. Lower the range by adjusting the 4 leveling legs alternatively until the range is level. Check if the range is level by placing a spirit level on the oven rack. Take 2 readings with the spirit level placed diagonally; take a reading in one direction and then in the other direction. Electrical Connection Requirements (Canada only) Plug the range cable (4 conductors) into a 4 conductor range outlet. Outlet must be properly grounded and in accordance with the Canadian Electrical Code (CSA Standard (C22. Only) This appliance must be properly installed and grounded by a qualified technician in accordance with the National Electrical Code ANSI/NFPA No. This appliance may be connected by means of permanent "Hard Wiring" or "Power Supply Cord Kit. " When hard wiring , do not leave excess wire in range compartment. Excess wire in the range compartment may not allow the access cover to be replaced properly, and could create a potential electrical hazard if wires become pinched. When using flexible conduit or range cable, use flex connector or range cable strain relief. The user is responsible for connecting the power supply cord to the connection block located behind the back panel access cover. This appliance may be connected by means of permanent "hard wiring"; flexible armored or nonmetallic shielded copper cable (when local code allow it) or by means of a power supply cord kit. NOTE: Electric slide-in range is shipped from factory with 1 1/8" (2. Risk of fire or electrical shock exists if an incorrect size range cord kit is used, the Installation Instructions are not followed, or the strain relief bracket is discarded. For mobile homes, new installation or recreational vehicles, use only a power cord kit design for a range at 125V /250V 50A recommended (minimum 40A). Cord must have either 3 (when local code permits grounding through neutral) or 4 conductors. Terminal on end of wires must be either closed loop or open spade lug with upturned ends. Do not loosen the nuts which secure the factory-installed range wiring to terminal block while connecting range. Electrical Shock Hazard • Electrical ground is required on this appliance. € Do not connect to the electrical supply until appliance is permanently grounded. [. . . ] 11): a) Connect the white appliance cable wire to the neutral (white) wire. D) Connect the green (or bare copper) grounding wire to the grounding wire of the circuit breaker, fuse box or junction box. -listed Conduit Connector (or CSA listed) Cable from Residence White Wire If the appliance is connected directly to the circuit breaker, fuse box or junction box, use flexible, armored or nonmetallic sheathed copper cable (with grounding wire). At the appliance end, the cable goes through the Direct Connection Hole (see Figure 9) on the Cord Mounting Plate. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE FRIGIDAIRE CPEH3077RF




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual FRIGIDAIRE CPEH3077RF will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.