User manual KARCHER HDS 12 14-4 ST GAS LPG

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KARCHER HDS 12 14-4 ST GAS LPG. We hope that this KARCHER HDS 12 14-4 ST GAS LPG user guide will be useful to you.


KARCHER HDS 12 14-4 ST GAS LPG : Download the complete user guide (18943 Ko)

Manual abstract: user guide KARCHER HDS 12 14-4 ST GAS LPG

Detailed instructions for use are in the User's Guide.

[. . . ] : Inbetriebnahme am: Prüfung durchgeführt am: Befund: Unterschrift Prüfung durchgeführt am: Befund: Unterschrift Prüfung durchgeführt am: Befund: Unterschrift Prüfung durchgeführt am: Befund: Unterschrift 22 DE - 20 Please read and comply with these original instructions prior to the initial operation of your appliance and store them for later use or subsequent owners. € Before first start-up it is definitely necessary to read the safety indications Nr. € In case of transport damage inform vendor immediately Symbols in the operating instructions ƽ Danger Immediate danger that can cause severe injury or even death. Warning Possible hazardous situation that could lead to severe injury or even death. [. . . ] Cleaning the Sieve in the water shortage See section "Clean sieve". Sieve safeguard after 500 - 700 op- Replace Electric igniter, ionisation elec- Replace electric igniter and/or the ionisation erating hours trode electrode. Hours check, clean Entire plant Visual inspection of the plant, check high pressure connections to see that they are not leaking, check that the over-flow valves are not leaking, check high pressure hoses, check pressure tanks, remove calcium deposits from the heating coil, clean/ replace ionisation electrodes, adjust burner. Hose switch annual Safety check Entire plant Perform a safety inspection as per the applicable national rules and regulations for liquid spray jets of the respective country. Time daily Activity Check handspray gun Assembly affected Hand spray gun of whom Operator Operator Operator Operator Operator Operator Operator Operator trained in decalcification Operator Customer Service Operator Customer Service Customer Service Technical expert EN -9 31 Maintenance contract You can enter into a maintenance contract with the concerned Kaercher Sales Office for the machine. Note: As an anti-corrosion measure and for neutralising the acid residue, we recommend that you finally pump an alkaline solution through the machine (for e. σ Cleaning the sieve  Assemble it back in the reverse sequence. σ Screw off supply hose at boiler bottom and drain heating spiral empty. Flush device with anti-freeze agent Note: Observe handling instructions of the anti-freeze agent manufacturer. σ Fill in normal anti-frost agents in the swimmer tank right until the top. σ Switch on the appliance and let it run until the safety mechanism against lack of water in swimmer tank gets activated and the machine is switched off. Descaling When there are deposits formed in the pipe connections, there is an increase in the flow resistance; this can cause the pressure switch to be triggered. Performance According to statutory requirements, only tested and approv approved boiler decrusting agents may be used. 287-013) dissolves the deposits that cannot be dissolved using RM 100. σ Connect the water hose directly to the pump and hang in the other free end into the container. σ Insert the connected spray pipe without nozzle into the container. σ Open the hand-spray gun and do not close it during the decalcification process. σ Switch on the appliance switch to "Burner on" until the temperature of approx. The main switch of the vacuum cleaner is to be switched off or the Cekon plug must be unplugged while carrying out any repairs or maintenance jobs. Fault Possible cause Machine is not running; indi- There is no voltage in the machine. Fuse in the control circuit (F3) has Install a new fuse; if it burns out again, then burnt off. + Indicator lamp for engine Thermal sensor (WS) in the engine Rectify cause for over-loading. [. . . ] This declaration shall cease to be valid if the machine is modified without our prior approval. 251-xxx Relevant EU Directives 2009/142/EC 2006/42/EC (+2009/127/EC) 2004/108/EC Applied harmonized standards EN 55014–1: 2006+A1: 2009+A2: 2011 EN 55014–2: 1997+A1: 2001+A2: 2008 EN 60335–1 EN 60335–2–79 EN 62233: 2008 EN 61000–3–2: 2006+A1: 2009+A2: 2009 HDS 12/14: EN 61000–3–3: 2008 HDS 9/16: EN 61000–3–11: 2000 Applied specifications: QA 195 (not LPG) Name of the appointed agency: for 2009/142/EC GASTEC Wilmersdorf 50 7327 AC Apeldoorn ID No. 957-648 The undersigned act on behalf and under the power of attorney of the company management. 28 - 40 71364 Winnenden (Germany) Phone: +49 7195 14-0 Fax: +49 7195 14-2212 Winnenden, 2010/12/01 Warranty The warranty terms published by our competent sales company are applicable in each country. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KARCHER HDS 12 14-4 ST GAS LPG




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KARCHER HDS 12 14-4 ST GAS LPG will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.