User manual KARCHER HKF 50 E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KARCHER HKF 50 E. We hope that this KARCHER HKF 50 E user guide will be useful to you.


KARCHER HKF 50 E : Download the complete user guide (794 Ko)

Manual abstract: user guide KARCHER HKF 50 E

Detailed instructions for use are in the User's Guide.

[. . . ] Risk of injury due to interior cleaner toppling over at low submerge depth. Risk of injury by toppling container therefore use extra support for container and interior cleaner. Danger of injury by interior cleaner sliding off; therefore tighten interior cleaner with clamping ring. Function – The interior cleaner consists of a drive unit, a support pipe and the cleaning head. [. . . ] € Zone 21 Zone 21 is an area where (during normal operation) dangerous explosionrisk atmosphere is present as a cloud of flammable dust in the air from time to time. € Zone 22 Zone 22 is an area where (during normal operation) dangerous explosionrisk atmosphere as a cloud of flammable dust is not normally present and if present, only for a short time. 7 8 9 10 11 12 13 14 15 16 The nominal pressure of the pump must not exceed 5 MPa when operating with solvents. The compressed air motor must only be operated once the interior cleaner has been filled with cleaning liquid. The operating temperature of the cleaning liquid water with cleaning agents must not must not exceed 95 °C. The operating temperature of the cleaning liquid solvents, brines and acids must not must not exceed 20 °C. The interior cleaner must be checked for flawless condition and smooth function after a certain operating time has passed (incl. The interior cleaner must only be used with cleaning liquids and in such media, whose affect on the materials is not damaging. Cleaning liquids that contain flammable solvent particles, must comply with the ignition groups IIA and IIB. The interior cleaner must not be constantly located in Zone 0, but only during the actual container cleaning. The operating guidelines as per BetrSichV as well as other national guidelines must be adhered to. Take into consideration, that the mixture of the container/ interior cleaner brought into the container is not resistant to breakdown from flames. hoses must be conductive (electrostatically) (resistance R < 1000 Ohm). Only cleaning agents with a conductivity G > 1000 pS/m may be used. Special conditions in the Ex area 1 2 3 4 The interior cleaner must only be used in Zone 0 if the containers are at least 1 m in diameter with the usual container height or do not exceed a comparable container size. The mass content of non-diluted solid substances in the cleaning liquid must not exceed 1%. The pump for the cleaning liquid must only be operated while it is filled with fluid. Operating pressure with solvent operation Voltage Current type Frequency Rated power Type of protection Compressed air Compressed air flow rate Functional speed - drive Sound pressure level (EN 60704-1) High pressure connection Minimum container opening Total length Max. +40 II 1/2 G c T4 II 1/3 D c 120 °C l/h (l/min) °C °C MPa (bar) MPa (bar) V -Hz W -MPa (bar) I/min 1/min dB(A) -mm mm mm kg °C Dimensional sheet sheet HKF 50 14 English Cleaning liquids solvents ƽ Danger The explosion protection must be taken into consideration when operating with solvents as well as in EX zones!€ Maximum pressure with solvent operation: 5 MPa ṇ Warning When operating with solvents, the sealing materials are less resistent, therefore they must be flushed immediately after use!1 Hydrocarbons Example: Petroleum 2 Aromates (solvents) Example: Benzene, toluene 3 Ketones Example: MEK (Methyle Ethyle Ketones), Acetone 4 Ester Example: Butylacetate, Methylacetate 5 Glycoles Example: Butyl glycole 6 Mixed solvents Example: Butyl acetate 85, Isobutyl acetate 85 (85 = 85% Butyl acetate + 15% n-Butanol) 7 Regenerates, distillates from different solvents, which have already been used for cleaning purposes or similar applications. 10%, without hypochlorite particles Acids ṇ Warning – The material will be worn off faster when using hydrochloric or sulfuric acids; therefore it must be rinsed/neutralised immediately! [. . . ] 957-453 Description Maintenance unit for compressed air (only for compressed air drive) Hole cone in PE design Locking screw (for 1 nozzle operation) Compressed air filter with automatic condensate drain (only for compressed air drive) Compressed air hose (sold by the meter) Exhaust air silencer with oil separator Order No. 2009) 2006/95/EC 2004/108/EC Applied harmonized standards EN 55014–1: 2006 EN 55014–2: 1997 + A1: 2001 EN 60204–1 EN 61000–3–2: 2006 EN 61000–3–3: 1995 + A1: 2001 + A2: 2005 II 1/3 D c 120 °C Warranty The warranty terms published by our competent sales company are applicable in each country. We will repair potential failures of the appliance within the warranty period free of charge, provided that such failure is caused by faulty material or defects in fabrication. In the event of a warranty claim please contact your dealer or the nearest authorized Customer Service centre. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KARCHER HKF 50 E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KARCHER HKF 50 E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.