If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual MAXDATA PLATINUM 1600 IR M2. We hope that this MAXDATA PLATINUM 1600 IR M2 user guide will be useful to you.
You may also download the following manuals related to this product:
MAXDATA PLATINUM 1600 IR M2 (2509 ko)
MAXDATA PLATINUM 1600 IR M2 (2510 ko)
MAXDATA PLATINUM 1600 IR M2 DATASHEET (369 ko)
MAXDATA PLATINUM 1600 IR M2 QUICK START (2622 ko)
MAXDATA PLATINUM 1600 IR M2 QUICK START (2623 ko)
MAXDATA PLATINUM 1600 IR M2 QUICK START (2620 ko)
Manual abstract: user guide MAXDATA PLATINUM 1600 IR M2
Detailed instructions for use are in the User's Guide.
[. . . ] MAXDATA Server PLATINUM 1600 IR
User's Manual
Contents
1 Setting up the System 7
Server Position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Connecting the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Rear of Server System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Control Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
2 Server System Features
11
Connector and Header Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Configuration Jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Light Guided Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 RAID Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Hardware Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 System Memory. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Available memory modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Memory Mirroring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Optional Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Remote Management Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Add-in I/O modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
3 Server Chassis Features
19
Component Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Internal Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 SAS/SATA Mid-Plane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0 Peripheral Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
4 Hardware Installations and Upgrades
23
Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Tools and Supplies Needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . System References . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Removing and Installing the Chassis Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Power down the server and unplug all peripheral devices and the AC power cable. Open the rear retention clip by pushing the blue slide upward and rotating clip to the fully open position (see letter "A"). Remove the filler panel from the selected add-in card slot (see letter "B"). Insert add-in card until it seats in riser card connector (see letter "C").
B
A
C
Figure 17. Close the retention clip.
/
Note
Make sure that all empty add-in card slots have filler panels installed. Plug all peripheral devices and the AC power cable(s) into the server.
Filling Empty Chassis Bays
A filler panel, drive blank, or empty drive carrier must be installed into any empty drive bay.
8
Hardware Installations and Upgrades
Installing Memory
The DIMMs are labelled as DIMM_A1 to DIMM_F on the board. First add a DIMM to the first socket of each of the following memory channels before installing DIMMs in the second socket of a channel. Distribute the memory evenly over both processors for systems with two processors. Please refer to Chapter for more detailed information on the system memory.
DIMM Blank Population
DIMM Blanks are required in order to maintain adequate thermal levels and airflow. The requirements are as follows: · One CPU installed - All CPU 1 DIMM slots (channels A, B, and C) must either have a DIMM or a DIMM blank installed. You may leave the CPU DIMM slots empty or store extra DIMM blanks in the blue DIMM slots. Two CPUs installed - All Blue DIMM slots (A1, B1, C1, D1, E1, F1) must either have a DIMM or a DIMM blank installed. You may store extra DIMM blanks in any unused CPU1 DIMM slots.
·
Installing DIMMs
To install DIMMs, follow these steps: 1. Make sure the clips at either end of the DIMM socket(s) are pushed outward to the open position. Holding the DIMM by the edges, remove it from its anti-static package. Align the small notch in the bottom edge of the DIMM with the key in the socket. When the DIMM is inserted, carefully push straight down on the top edge of the DIMM until the retaining clips snap into place. Replace the chassis cover and reconnect the AC power cord.
MAXDATA Server PLATINUM 1600 IR M
9
Installing or Replacing the Processor
CAUTIONS
Processor must be appropriate: You may damage the server board if you install a processor that is inappropriate for your server. ESD and handling processors: Reduce the risk of electrostatic discharge (ESD) damage to the processor by doing the following: (1) Touch the metal chassis before touching the processor or server board. Keep part of your body in contact with the metal chassis to dissipate the static charge while handling the processor. () Avoid moving around unnecessarily.
Installing the Processor
To install a processor, follow these instructions: 1. Locate the processor socket and raise the socket handle completely (see Figure 19).
Figure 19. [. . . ] Green = No Fault Green blinking = degraded condition Amber blinking = non-critical error Amber = critical or nonrecoverable error
ID
Aid in server identification from the back panel Visible fault warning
Front control panel and board rear left corner Control panel and board rear right corner
Blue
System Status
Green or Amber
MAXDATA Server PLATINUM 1600 IR M
41
4
7 Technical Reference
Power Supply Specifications
Power Supply Input Voltages
· · 100-17 V at 50/60 Hz; 8 A max. 00-40 V at 50/60 Hz; 4 A max.
Efficiency
The following table shows the efficiency of the power supply with an input voltage of 0 volts.
Table 6. Efficiency of the power supply Load (% of maximum) Efficiency 20% 81% 50% 85% 100% 81%
Power Supply Output Voltages
The table below lists the total wattage available from the power subsystem for each voltage. Ensure that your loads do not exceed the combined total wattage of 650 Watts.
Table 7. [. . . ]