[. . . ] Order No: MAC0510072C2
Air Conditioner
CS-E9EKEB CU-E9EKEB CS-E12EKEB CU-E12EKEB
CONTENTS
Page
1 Safety Precautions 2 Specification 2. 1. Powerful Heating And Top-class Energy Effciency 4 Location of controls and components 4. 1. Outdoor Unit 3 5 5 7 9 9 9 9 9 10 10 10 10 11 11 12 © 2005 Panasonic HA Air-Conditioning (M) Sdn Bhd (11969-T). Outdoor Unit
Page
13 14 15 15 16 17 17 19 21 21 22 23 23 24 27
CS-E9EKEB CU-E9EKEB / CS-E12EKEB CU-E12EKEB
12 Operation And Control 12. 1. [. . . ] · Ensure the difference between the intake temperature and the discharge is more than 8°C.
29
CS-E9EKEB CU-E9EKEB / CS-E12EKEB CU-E12EKEB
12 Operation And Control
12. 1. Basic Function
Inverter control, which equipped with a microcomputer in determining the most suitable operating mode as time passes, automatically adjusts output power for maximum comfort always. In order to achieve the suitable operating mode, the microcomputer maintains the set temperature by measuring the temperature of the environment and performing temperature shifting. The compressor at outdoor unit is operating following the frequency instructed by the microcomputer at indoor unit that judging the condition according to internal setting temperature and intake air temperature.
12. 1. 1. Internal Setting Temperature
Once the operation starts, remote control setting temperature will be taken as base value for temperature shifting processes. These shifting processes are depending on the air conditioner settings and the operation environment. The final shifted value will be used as internal setting temperature and it is updated continuously whenever the electrical power is supplied to the unit.
12. 1. 2. There are two types of airflow, vertical airflow (directed by horizontal vane) and horizontal airflow (directed by vertical vanes). Control of airflow direction can be automatic (angles of direction is determined by operation mode, heat exchanger temperature and intake air temperature) and manual (angles of direction can be adjusted using remote control).
12. 1. 2. 1. Vertical Airflow
Operation Mode Heating Airflow Direction 1 Auto with Heat Exchanger Temperature A B C D Upward fix Downward fix Upward fix Downward fix 3 8 8 Vane Angle (°) 2 3 4 3 64 3 3 17 33 49 8 ~ 36 15 22 30 8 15 22 30 5
Cooling, Soft Dry and Ion Mode Judgment in Auto
Manual Auto Manual Auto Manual
63 36 36
1. Automatic vertical airflow direction can be set using remote control; the vane swings up and down within the angles as stated above. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1 below. When the air conditioner is stopped using remote control, the vane will shift to close position. Manual vertical airflow direction can be set using remote control; the angles of the vane are as stated above and the positions of the vane are as Figure 2 below. When the air conditioner is stopped using remote control, the vane will shift to close position.
30
CS-E9EKEB CU-E9EKEB / CS-E12EKEB CU-E12EKEB
12. 1. 2. 2. Automatic horizontal airflow direction can be set using remote control; the vane swings left and right within the angles as stated below. For heating mode operation, the angle of the vane depends on the indoor heat exchanger temperature as Figure 1 below.
Operation Mode Heating, with heat exchanger temperature Cooling, Soft Dry and Ion A B Vane Angle (°) 65 ~ 115 90 65 ~ 115
2. Manual horizontal airflow direction can be set using remote control; the angles of the vane are as stated below and the positions of the vane are as Figure 2 above.
Pattern Airflow Direction Patterns at Remote Control Vane Angle (°) 1 2 3 4 5
90
65
78
102
115
12. 1. 3. Purpose To provide quiet cooling operation compare to normal operation. Quiet operation start condition · When "quiet" button at remote control is pressed. When one of the following conditions is satisfied, quiet operation stops: a. When quiet operation is stopped, operation is shifted to normal operation with previous setting. [. . . ] · There are many high voltage components within the heat sink cover so never touch the interior during operation. Indoor Electronic Controller and Control Board
41
CS-E9EKEB CU-E9EKEB / CS-E12EKEB CU-E12EKEB
42
CS-E9EKEB CU-E9EKEB / CS-E12EKEB CU-E12EKEB
15. 2. Indoor Cross Flow Fan and Fan Motor
43
CS-E9EKEB CU-E9EKEB / CS-E12EKEB CU-E12EKEB
44
CS-E9EKEB CU-E9EKEB / CS-E12EKEB CU-E12EKEB
15. 3. Outdoor Propeller Fan and Fan Motor
45
CS-E9EKEB CU-E9EKEB / CS-E12EKEB CU-E12EKEB
46
CS-E9EKEB CU-E9EKEB / CS-E12EKEB CU-E12EKEB
16 Technical Data
16. 1. [. . . ]