User manual PANASONIC KX-TD1232E
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PANASONIC KX-TD1232E. We hope that this PANASONIC KX-TD1232E user guide will be useful to you.
Manual abstract: user guide PANASONIC KX-TD1232E
Detailed instructions for use are in the User's Guide.
[. . . ] Digital Super Hybrid System
Please read this manual before connecting the Digital Super Hybrid System.
DIGITAL SUPER HYBRID
D1232
SYSTEM
DIGITAL SUPER
D816
HYBRID SYSTE M
MODEL KX-TD816E / KX-TD1232E
Panaso
nic
Panaso
nic
KX-TD816
KX-TD1232
Thank you for purchasing the Panasonic Model KX-TD816E/KX-TD1232E, Digital Super Hybrid System.
System Components
Model Service Unit Telephone KX-TD816E KX-TD1232E KX-T7420E KX-T7425E KX-T7431E KX-T7433E KX-T7436E KX-T7220E KX-T7230E KX-T7235E KX-T7250E KX-T7130E KX-T7020E KX-T7050E KX-T7440E KX-T7441E KX-T7240E KX-T7040E KX-TD170E KX-TD180E KX-TD181E*1 KX-TD182E*2 KX-TD190E KX-TD192E*1 KX-TD196E*1 KX-TD197E KX-TD198E*2 KX-TD199E*2 KX-TD280E KX-TD281E*1 KX-TD282E*2 KX-TD286E KX-TD290E KX-TD142 KX-TD144 KX-TD146 KX-T30865E KX-A46E Description Digital Super Hybrid System (Main Unit) Digital Super Hybrid System (Main Unit) Digital proprietary telephone Digital proprietary telephone Digital proprietary telephone with 1-line display Digital proprietary telephone with 3-line display Digital proprietary telephone with 6-line display Digital proprietary telephone Digital proprietary telephone with 2-line display Digital proprietary telephone with 6-line display Digital proprietary telephone Proprietary telephone with 1-line display Proprietary telephone Proprietary telephone Digital DSS Console Digital Attendant Console Digital DSS Console DSS Console 8-Station Line Unit 4-CO Line Unit 8-CO Line Card 4-CO Line Card Message Unit System Inter Connection Card (two cards with Connection Cable) Remote Card 9600bps Speed Remote Card 9600bps Speed Remote Unit Message Card 2-ISDN S0 Line Unit 4-ISDN S0 Line Card 2-ISDN S0 Line Card 6-ISDN S0 Line Unit Primary Rate Interface (PRI) ISDN Expansion Unit Cell Station Cell Station Interface Unit Doorphone Battery Adaptor
Optional Equipment
System Components Table
Note In this Installation Manual, the suffix "E" of each model number is omitted. The Digital Super Hybrid System is abbreviated as "DSHS. " The Digital Proprietary Telephone is abbreviated as "DPT. " Other proprietary telephone (analogue type) is abbreviated as "APT. " A Single Line Telephone is abbreviated as "SLT. "
2
*1: Available for KX-TD1232 only. *2: Available for KX-TD816 only.
Important Information
FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CAREFULLY.
This appliance is supplied with a moulded three pin mains plug for your safety and convenience. Should the fuse need to be replaced please ensure that the replacement fuse has a rating of 5 amps and that it is approved by ASTA or BSI to BS1362. [. . . ] · CO line group number: 1 through 8, ( =all CO line groups) · Time (seconds): 1. 5 / 2. 5 / 3. 5 / 4. 5 / 5. 5 / 6. 5 All CO line groups 3. 5 s 1. Enter 412.
Display: TRG Pause Time
Selection Default Programming
2.
Press NEXT.
Display: TRK GRP NO?>
3.
Enter a CO line group number.
To enter CO line group number 1, you can also press NEXT. To program another CO line group, press NEXT or PREV, or SELECT and the desired CO line group number. 8.
Conditions
· To assign all CO line groups to one selection, press the key at step 3. In this case, the display shows the contents programmed for CO line group 1. · Program [401] "CO Line Group Assignment" is used to assign each CO line to a CO line group. · If the programmed pause time is 1. 5 or 2. 5 seconds and you are storing an external number in program [001] "System Speed Dialling Number Set, " it is required to store a pause manually after the line access code. Section 3, Features, Host PBX Access
Feature References
Pause Insertion, Automatic
System Programming
4-99
413
Description
4. 6
CO Line Programming
Register Recall Signal Time
Assigns the length of the register recall signal time. If your system is installed behind a host PBX, External Feature Access (EFA) is necessary to obtain its services. To enable it, select a required register recall signal sending time for the CO line group. · CO line group (TRG) number: 1 through 8, ( =all CO line groups) · Time (milliseconds): Disable (no EFA) / 80 / 96 / 112 / 200 / 300 / 400 / 500 / 600 / 700 / 800 / 900 / 1000 / 1100 / 1200 All CO line groups 96 ms 1. Enter 413.
Display: Register Recall
Selection
Default Programming
Press NEXT.
Display: TRK GRP NO?>
Enter a CO line group number.
To enter CO line group number 1, you can also press NEXT. To program another CO line group, press NEXT or PREV, or SELECT and the desired CO line group number. Press END.
Conditions
· You may disable EFA, if not required. Program [414] "Disconnect Time" is used to select the time required for the Recall feature. · The register recall signal time required is determined by the central office or the host PBX lines. · To assign all CO line groups to one selection, press the key at step 3. In this case, the display shows the contents programmed for CO line group 1. · Program [401] "CO Line Group Assignment" is used to assign each CO line to a CO line group. Section 3, Features, External Feature Access Recall
Feature References
4-100
System Programming
4. 6
Description Selection
CO Line Programming
Disconnect Time
414
Determines the amount of time between successive accesses to the same CO line. · CO line group (TRG) number: 1 through 8, ( =all CO line groups) · Time (seconds): 0. 5 / 2. 0 / 4. 0 All CO line groups 2. 0 s 1. Enter 414.
Display: TRG Discnct Time
Default Programming
2.
Press NEXT.
Display : TRK GRP NO?>
3.
Enter a CO line group number.
To program CO line group number 1, you can also press NEXT. [. . . ] Intercept Routing - Night PS Charge Limit PS CLIP/COLP Number Assignment PS Class Of Service PS Data Line Security PS Voice Mail Access Code PS Incoming Display PS Outgoing Permitted Day PS Outgoing Permitted - Night PS DIL 1 : N - Day PS DIL 1 : N Night PS Password Set : 1234 (Default) SXDP Assignment : Enable (Default) Setting Super eXtra Device Port : User Programming Flexible Key Programming
3
[ 17 ] PS Settings 2
[ 18 ] PS Settings 3
[ 19 ] PS Settings 4 [ 20 ] PS Settings 5 [ 21 ] PS Settings 6
[ 22 ] PS Flexible Programming
[020]
Site Surveying
Preparing for the Site Survey · Program PBX. · Assign the CS ID to the PS (CS ID is only available from the PC Programming Tool). · Change DIP switches to Test Mode ( at the rear of the TD142 ). · Connect TD142 to Power Supply.
Assigning a PS ( TD7500 ) to a Cell Station To enter Survey Mode : Switch PS On while pressing, `TALK' + `FLASH ( )' + `*'
.
Step [2]
1~8 [ TALK ] [ CS ID ] [ TALK ] [ CLR ]
Display : Entry FUNCTION < 0 4 > CS NO? [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC KX-TD1232E
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC KX-TD1232E will begin.