User manual VDO KIBES BROCHURE
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VDO KIBES. We hope that this VDO KIBES user guide will be useful to you.
Manual abstract: user guide VDO KIBESBROCHURE
Detailed instructions for use are in the User's Guide.
[. . . ] KIBES
Multiplex system for buses and special vehicles
Overview
VDV Driver Workplace
MOKI
DMUX-C / DMUX-M
Instrumentation CAN
Body CAN
Powertrain CAN (SAE J199) Central Computer ZR-A
EDC
Diagnostic and Programming (K-LINE / KWP000) Multiplex CAN 1 Multiplex CAN
ABS
Gearbox
MUX-B
MUX-B
MUX-M
MUX-M
MUX-P
SMUX000
Battery Power
In modern vehicles increasing requirements regarding efficiency, comfort and functionality effect the development. [. . . ] door control MTS, Pronova; Generic CAN Objects (10 rx / tx) IBIS Interface Yes (VDV 00; 198/199) RS Interface only (prepared for (Modem interface) optional Remote Diagnostic) SAE J187/J1708 Rx only Digital Output 7+ (100 mA Low Side) Digital Input 7 (alternative to 7 Outputs) Wake Up signals EOL programming K-Line interface (KWP000) Diagnostic Service K-Line interface (KWP000; ASAM)
MUX-B / MUX-P
Multiplex Node MUX-B
Generic multiplex node for general purpose Built in diagnostic & protection capabilities Multiple input & output capabilities Designed for cabin installation Client operation mode
Intelligent Multiplex Node MUX-P
Programmable multiplex node for chassis installation Built in diagnostic & protection capabilities Water-proofed, robust housing High output current capability Master or client operation mode Model Based Application programming tool KIBES- (PLC according to IEC 6111-)
Specifications Dimensions (mm) Nominal voltage Supply voltage Operating temperature Protection degree Features CAN INPUT digital analog (parametric) OUTPUT High Side 1. 6 A 10 A 9. of Power supply groups (1 A) Wake Up signals EOL programming Diagnostic Service
Specifications Dimensions (mm) Nominal voltage Supply voltage Operating temperature Protection degree Features CAN INPUT digital analog (parametric) OUTPUT High Side 1 A 10 A 6A A A 1. of Power supply groups (1 A)
8 x 1 x 0 1 V and V 8 V to V -0 °C to +70 °C IP 0
99 x 17 x 7, 1 V 9 V to 16 V -0 °C to +8 °C IP 67 / IP6K9K
ISO 11898 6 10 8 ( A at 10 % duty each) 8 0 A
SAE J199 17 1 (PWM) 1 9 1 8 1 K-Line interface (KWP000) K-Line interface (KWP000; ASAM)
6
7
DMUX-C / DMUX-M / MOKI
Display Multiplex Node DMUX
Generic graphic display unit for general purpose Video signals input (only DMUX-C) Inputs & outputs to connect switches and indicator LED`s Application programming via CAVTAN software
Specifications Dimensions (mm) Nominal voltage Supply voltage Standby current consumption Operating temperature Storage temperature Protection degree Features CAN I_CAN MC_CAN Res_CAN Video input for cameras Display resolution (pixel) Visibility (mm) Technology Illumination Dimming Heating DMUX-C DMUX-M 17. 1 x 17. 1 x 18. to 0 V mA -0 °C to +0 °C -0 °C to +80 °C -0 °C to +70 °C -0 °C to +80 °C IP 0 DMUX-M
MOKI (Modular instrument cluster)
Generic modular instrument cluster for general purpose Connects directly to KIBES multiplex system via CAN Mid-line MOKI-ML with integrated DMUX-M High-line MOKI-HL with integrated DMUX-C
Specifications Dimensions (mm) Nominal voltage Supply voltage Operating temperature (LCD) Protection degree
0. 1 x 1 x 88. 8 V 1. to 0V -0 °C to +70 °C IP front side mounted IP0 rear side mounted
DMUX-C
Features CAN Hardware and equipment E-Speedo (ET) Tachometer (RPM)
ISO 11898 up to 8 stepper motors
ISO 11898 ISO 1119 ISO 11898 (optional) PAL / NTSC 0 x 101 x 7 Color TFT CCFL yes yes 160 x 18 9 x 76 Monochrome FSTN LED yes no
7 segment LCD for distance / time in the electronic speedometer area optional: two-line / segment display 1 warning sign each for TCO and RPM in the scale range Small gauges Operating telltale Negative print Standard 8, max. 6 hot keys Display module DMUX colour or DMUX monochrome Status telltale module LED Analog inputs Analog inputs 7 mA 1 Analog input mA Status inputs max. diagnosticable inputs Pulse inputs equal Pulse inputs, Speedo and RPM 9
8
SMUX000 / VDV / KIBES-
Multiplex Switch SMUX000
High flexibility Reduces cable harness within dash
Specifications Dimensions (mm) Nominal voltage Supply voltage Stand-by current consumption Operating temperature Protection degree
KIBES- Software
The KIBES- software tool is required To develop the PLC application program and support the programming languages ladder logic, function block diagram, sequential function chart, structured text To test the PLC application program offline and online To download the PLC application program Runtime version with limited functionality for service and EOL programming
Features SW package to develop the PLC application program for the Central computer ZR-A Object-oriented programming system according to IEC 6111- Supporting the IEC-languages FBD (Function Block Diagram), SFC (Sequential Function Chart), ST (Structured Text) and LLP Ladder logic programming Offline simulation and online test fully graphical Version and revision management Automated program generation (patch generator) C-code generator inclusive adjustable standard kernel Free design of documentation
1 x x 0 1 V and V 10. 8 V to V . connector
Features CAN Interface to client Switches master Switches client Dimming (PWM)
ISO 11898 max. [. . . ] We reserve the right to change delivery options and to make technical changes. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE VDO KIBES
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VDO KIBES will begin.